@jbeale1 wrote:
I’m a HA and Zwave total beginner, running HA 0.103.6 on RPi4. I have one controller: Zooz S2 USB stick, and exactly one device: EVALogik ZW39 Z-Wave Smart Plug (Dimmer). There is one entry for each of those things shown at http://192.168.1.239:8123/config/devices/dashboard
However on http://192.168.1.239:8123/developer-tools/state I see three related entries:
zwave.zooz_zst10_s2_z_wave_plus_usb_stick
zwave.inovelli_unknown_type_c000_id_c002
light.inovelli_unknown_type_c000_id_c002_levelNow when I turn the dimmer on and off with its own hardware button, it works, and I know the Zwave info is transmitted because each state change is logged correctly on the GUI window at http://192.168.1.239:8123/logbook and also shows correctly in the timeline at http://192.168.1.239:8123/history
However my attempts to control this device by creating a new automation at http://192.168.1.239:8123/config/automation
are so far unsuccessful. Under Config/Devices/Device Info/Entities I see there are two different things (“Entities”?) shown, one with a Zwave icon and one with a lightbulb icon. I am wondering if I am trying to control the Zwave part, but what I need is the dimmer (lightbulb) part, with name ending in “…c002_level” (or the other way around?) Does this make any sense?When I manually trigger my automation attempting to turn on the light, I do see something appear from that moment in time in the “OZW log” at http://192.168.1.239:8123/config/zwave, but with no resulting effect at the actual dimmer. For example, the log result of my automation triggering:
2020-01-14 21:20:25.480 Info, Node005, Value::Set - COMMAND_CLASS_SWITCH_MULTILEVEL - Level - 0 - 1 - 255 2020-01-14 21:20:25.480 Info, Node005, SwitchMultilevel::Set - Setting to level 255 2020-01-14 21:20:25.480 Detail, Node005, Queuing (Send) SwitchMultilevelCmd_Set (Node=5): 0x01, 0x0a, 0x00, 0x13, 0x05, 0x03, 0x26, 0x01, 0xff, 0x25, 0x87, 0x9a 2020-01-14 21:20:25.480 Detail, Node005, Queuing (Send) SwitchMultilevelCmd_Get (Node=5): 0x01, 0x09, 0x00, 0x13, 0x05, 0x02, 0x26, 0x02, 0x25, 0x88, 0x6b
By contrast, this is what the log says after a manual turn on with the hardware button:
2020-01-14 21:27:40.926 Detail, Node005, Received: 0x01, 0x0b, 0x00, 0x04, 0x10, 0x05, 0x03, 0x20, 0x03, 0x63, 0xde, 0x00, 0x78 2020-01-14 21:27:40.926 Detail, 2020-01-14 21:27:40.926 Info, Node005, Received Basic report from node 5: level=99 2020-01-14 21:27:40.926 Detail, Node005, Queuing (Send) SwitchMultilevelCmd_Get (Node=5): 0x01, 0x09, 0x00, 0x13, 0x05, 0x02, 0x26, 0x02, 0x25, 0x89, 0x6a 2020-01-14 21:27:41.376 Detail, Node005, Received: 0x01, 0x0d, 0x00, 0x04, 0x10, 0x05, 0x05, 0x26, 0x03, 0x63, 0x63, 0x00, 0xde, 0x00, 0x1d 2020-01-14 21:27:41.376 Detail, 2020-01-14 21:27:41.376 Info, Node005, Received SwitchMultiLevel report: level=99 2020-01-14 21:27:41.376 Detail, Node005, Refreshed Value: old value=0, new value=99, type=byte 2020-01-14 21:27:41.376 Detail, Node005, Changes to this value are not verified 2020-01-14 21:27:41.377 Detail, Node005, Notification: ValueChanged
Here are the two device listing:
light.inovelli_unknown_type_c000_id_c002_level off node_id: 5 value_index: 0 value_instance: 1 value_id: 72057594126630913 friendly_name: Garage_Dimmer_1 supported_features: 1
zwave.inovelli_unknown_type_c000_id_c002 ready node_id: 5 node_name: Inovelli Unknown: type=c000, id=c002 manufacturer_name: Inovelli product_name: Unknown: type=c000, id=c002 query_stage: Complete is_awake: true is_ready: true is_failed: false is_info_received: true max_baud_rate: 40000 is_zwave_plus: true capabilities: routing,beaming,listening,zwave_plus neighbors: 1 sentCnt: 20 sentFailed: 0 retries: 0 receivedCnt: 28 receivedDups: 0 receivedUnsolicited: 16 sentTS: 2020-01-14 18:46:48:143 receivedTS: 2020-01-14 21:27:41:376 lastRequestRTT: 32 averageRequestRTT: 31 lastResponseRTT: 98 averageResponseRTT: 72 application_version: 2.00 friendly_name: Dimmer1
Posts: 2
Participants: 2