@Jamie_Pryer wrote:
Hey,
i have a honeywell system.
goal: notify when the hotwater falls below “28”my entity for the water (see below) shows a state of “off/on”, however there is an attribute which is the temperate itself. (current_temperature).
so i created the following 2 template values to be able to use this in the automation:
hotwater_temperature_tracker: friendly_name: "Hot Water Temperature Tracker" unit_of_measurement: "°C" value_template: "{{ state_attr('water_heater.dhw_controller', 'current_temperature') }}" hotwater_temperature_tracker_numeric: friendly_name: "Hot Water Temperature Tracker Numeric" value_template: '{{ float(states.water_heater.dhw_controller.attributes["current_temperature"]) }}'
my automation however, doesnt work, when i try either template values?
- alias: hot water temp below 28 trigger: platform: numeric_state entity_id: sensor.hotwater_temperature_tracker_numeric above: 0 below: 28 #for: #minutes: 15 action: - service: persistent_notification.create data_template: message: 'Hot water temperature is low, its now at: {{ sensor.hotwater_temperature_tracker_numeric }}' title: Hot Water below 28 - service: notify.notify data_template: message: 'Hot water temperature is low, its now at: {{ sensor.hotwater_temperature_tracker_numeric }}' title: hot Water below 28 id: hotwateralert
Posts: 2