@mstudent100 wrote:
Got my boiler system integrated into HA using ESPhome and relays (6 different zones, 10 total zone valves). I’ve got an automation that locks out the boiler based on my weather station outside temp @ 65 degrees F:
- id: '1580599005490' alias: Boiler Lockout description: '' trigger: - above: '-50' below: '65' entity_id: sensor.el_rancho_estudiante_temp platform: numeric_state condition: [] action: - entity_id: switch.relay_channel_1_2 service: switch.turn_on
The switch.relay_channel_1_2 is the boiler start/stop.
climate: - platform: generic_thermostat name: Family room heater: switch.relay_channel_2_2 target_sensor: sensor.lumi_lumi_weather_12114a04_temperature min_temp: 62 max_temp: 75
Turns on the zone valves for the family room.
My question is, along with the outdoor air temperature, is there any way to stop the boiler if none of the zones are calling? The boiler continues to run (it has its own loop, so it does have a “load”) but it seems unnecessary to have it run with no zones needing heat.