@Morpheas1983 wrote:
Hello everyone,
I hope I am posting at the right place… This is my first post!
after searching for houres, and not finding any helpful posts, i would like to share my problem with the community.
I am trying to set up a custome thermostate, using a nodumcu (through ESPHome) a Nextion display and a Generic Thermostat from Home Assistant.
The plan is the following:
- display the current temperature, humidity, and target temperature to the Nextion Display
- display the current temperature, humidity, and target temperature to the thermostate card in lovelace
- “conect” the target temperature of nextion display and thermostat card, so when changing the target temperature from the display, the lovelace card is being change as well and vice versa.
So far, 1 and 2 are working fine, but I am having difficulties on number 3.
Following are the YAML files of the ESPHome and the Home Assistant configuration
ESPHome YAML:
esphome: name: esp2 platform: ESP8266 board: nodemcuv2 wifi: ssid: "***" password: "****" manual_ip: static_ip: 192.168.1.113 gateway: 192.168.1.1 subnet: 255.255.255.0 dns1: 192.168.1.1 dns2: 192.168.1.1 # Enable fallback hotspot (captive portal) in case wifi connection fails ap: ssid: "****" password: "****" captive_portal: # Enable logging logger: # Enable Home Assistant API api: ota: sensor: - platform: dht pin: D3 model: dht11 temperature: name: "Thermostat Temperature" id: therm_temp humidity: name: "Thermostat Humidity" id: therm_hum update_interval: 30s - platform: homeassistant id: temperature_thermostat entity_id: sensor.thermostat_temperature - platform: homeassistant id: humidity_thermostat entity_id: sensor.thermostate_humidity - platform: template name: "Set Temperature" lambda: |- return {id(set_temp)}; update_interval: 1s switch: - platform: gpio name: "Heater" id: heater pin: D5 inverted: yes binary_sensor: - platform: gpio pin: number: D7 mode: INPUT_PULLUP inverted: yes id: 'bouton_heater' name: "Bouton Heater" on_state: then: - switch.toggle: heater - platform: nextion page_id: 0 component_id: 6 id: minus_set_temp name: "Minus Set Temperature" on_press: lambda: |- id(set_temp) = id(set_temp) - 1; if (id(set_temp) == 14){ id(set_temp) = 15; } - platform: nextion page_id: 0 component_id: 5 id: plus_set_temp name: "Plus Set Temperature" on_press: lambda: |- id(set_temp) = id(set_temp) + 1; if (id(set_temp) == 36){ id(set_temp) = 35; } i2c: display: - platform: nextion id: teplomer update_interval: 1s lambda: |- // Do not wait for ack (this delays the whole procedure a lot, and has no use) it.set_wait_for_ack(false); it.set_component_text_printf("temperature","%2.1f",id(therm_temp).state); it.set_component_text_printf("humidity","%2.1f",id(therm_hum).state); it.send_command_printf("n0.val=%d",id(set_temp)); it.send_command_printf("n1.val=%d",id(set_temp)); uart: rx_pin: GPIO1 tx_pin: GPIO3 baud_rate: 9600 globals: - id: set_temp type: int initial_value: '15' restore_value: no
configuration YAML: (only what is relevant)
climate: - platform: generic_thermostat name: Heater heater: switch.heater target_sensor: sensor.thermostat_temperature min_temp: 15
So the question is, what do I have to do, in order to connect “set_temp” from the ESPHome YAML (the dispay variable) with the thermostat target temperature, so when I change, the other changes as well.
In the configuration YAML I also tryied to do this:
set_temp: '{{ ((states(''sensor.set_temperature_2'') }}'
but it does not convert to float, so no luck theire!
Any help will be much appreciate!!
Thank you in advance.
Posts: 1